| General Requirements |
| Product/Feature |
Requirement |
Specification (Tier 1) |
| Applicable for all Abaqus products supported
on this platform |
Processor |
Itanium II |
| OS Level |
SuSE Linux Enterprise Server 9.01 |
Notes:
1 Other supported operating systems and versions
are listed below under Additional Test Configurations. |
| Additional Requirements
for specific Abaqus Products and Features |
| Product/Feature |
Requirement |
Specification (Tier 1) |
| Abaqus/CAE, Abaqus/Viewer |
Graphics |
Interactive products are not supported
on this platform |
| Building post processing applications (Abaqus make utility
with C++) |
C++ Compiler |
Intel Itanium C++ Compiler Version 8.1.021 |
| User Subroutines and building post processing applications
with Fortran (Abaqus make utility with Fortran and Abaqus user subroutines) |
Fortran Compiler |
Intel Itanium Fortran Compiler Version 8.1.018 |
Abaqus/Standard & Abaqus/Explicit
MPI based parallel execution |
MPI |
HP-MPI 2.2.0 (distributed on the Abaqus CD) |
Abaqus/Standard & Abaqus/Explicit
MPI-based Distributed Memory Parallel execution |
Interconnect for DMP |
Ethernet 1000 Mbps |
| FSI Co-simulation using MpCCI |
MpCCI
(Fraunhofer
SCAI) |
MpCCI Version 3.0.52 |
| Abaqus installation |
CD-ROM |
Mounted automatically |
| 2SIMULIA intends to qualify and support Abaqus Version 6.6 with MpCCI 3.0.5 and FLUENT 6.3. However, delays with the official release of both MpCCI 3.0.5 and FLUENT 6.3 caused full qualification of FSI Co-simulation to lag the release of Abaqus V6.6. In the interim, FSI Co-simulation using MpCCI with Abaqus Version 6.6 has been partially qualified using pre-release versions of MpCCI 3.0.5 and FLUENT 6.3. Until qualification can be completed with released versions of MpCCI and Fluent; SIMULIA recommends that interested FSI users continue to use Abaqus V6.5, MpCCI 3.0.4 and FLUENT 6.2.16. Check back for new information which will be posted here as qualification progresses for FSI Co-simulation. |